Available in 9.7.X and above
Overview
The purpose of the VFC to WFE Metadata Integrator tool is to import call metadata, supported by switch platform and user data, from the VFC platform to the Verint v15.2 Workforce Engagement (WFE) suite. Once imported, the data is available for use by certain applications within the WFE suite. The Integrator continuously verifies the data in both VFC and WFE and carries out a one-way synchronization periodically.
This integration offers the following features:
- Migration of call record metadata and their related audio quality, speech transcription, and screen recording metadata from VFC to WFE.
- Migration of switch platforms, and extensions from VFC to WFE.
- Migration of groups and users from VFC to WFE.
The data synchronized to Workforce Engagement is then available for use in certain WFE applications:
- You can configure Capture Verification Collectors to collect Call Detail Records (CDRs) from the switch platforms and verify your call recording, audio quality, audio transcription, archiving, screen recording, and sensitive data masking compliance with Automated Verification.
- You can create Automated Verification reports to summarize your recording compliance results.
Design your integration based on your VFC and WFE deployments using this document before installing and configuring the Integrator.
Supported switch platforms
The Integrator supports the synchronization of recording data for the following switch platforms:
- Avaya DMCC/MR
- Cisco Network Based
Minimum software version
- VFC Capture 9.7.X or higher
- Workforce Engagement v15.2
Concepts and functionality
Architecture
The Integrator connects to the VFC Media Repository through API calls to gather system information and sets up an SQL connection to the VFC database to read in the data to synchronize. The Integrator communicates with WFE services and sends data to the WFE database using API calls.
The Integrator supports the following deployments:
System | On premise | Single-tenant Cloud | Multi-tenant Cloud |
VFC | Yes | Yes | Yes * |
WFE | Yes | Yes | Yes |
* Multi-tenant cloud VFC deployments are supported if each tenant has its own Integrator configured.
The Integrator must be installed on a VFC server. Only one Integrator can be installed on a single server.
When the Integrator first runs, it creates its editable configuration file, appsettings.<environmentName>.json. All connection details are specified in this file, along with parameters to monitor and optimize the synchronization process. The default value of environmentName is Production, otherwise, if configured, the value matches the environment variable DOTNET_ENVIRONMENT. Any references to appsettings.Production apply to this file.
There can only be one Integrator running per VFC environment. There can be multiple idle Integrators configured for the same environment, which take over if the active Integrator fails. An Integrator and a VFC environment are associated by configuring the Environment ID in the appsettings.Production configuration file of the Integrator. If multiple VFC environments use the same VFC database, the active Integrator of each environment can connect to that database at the same time. See Resilience for more information.
An Integrator synchronizes VFC data to a single WFE tenant. The connection to the WFE installation is specified by configuring the URL of the WFE Application Server on which the WFO_ProductionDomain_ProductionServer runs. Multiple Integrators can synchronize data to a single WFE tenant, but there are parameters in the appsettings.Production file that must be unique to each connected Integrator. Refer to the Configuration Guide for more details. The tenant to which an Integrator connects is specified by creating an API token for the tenant in WFE and adding that token to the Integrator configuration.
User groups
The Integrator synchronizes all user data from the VFC database to WFE, recreating the same group structure in WFE as it exists in VFC.
While organizations do not exist in VFC, WFE relies on organizations for enforcing user access scoping, and logically associating users and data sources. As the first step of the deployment process, the Integrator requires the creation of a parent organization in WFE. This organization can be on any level of an existing WFE organizational hierarchy. The name of the parent organization must be added to the Integrator configuration. The user groups and data sources managed by the integration are associated with the organization upon creation.
The parent organization must not be the Root organization that is created during the WFE deployment process.
You must also manually create a parent WFE group that holds all groups of VFC synchronized employees, and the name must be added to the Integrator configuration.
The parent group must not have employees assigned to it at any point in time and it must not be the Root group that is created during the WFE installation process.
Under the parent group, a default group holds all individual VFC synchronized employees, regardless of what VFC groups those employees belong to. On the same hierarchical level, under the parent group, the WFE groups matching the VFC groups get automatically created by the integrator. They retain their VFC names, with the configured name prefix.
Changes to users or groups that happen in VFC are applied to their WFE equivalent the next time the synchronization process runs. Changes to users or groups that happen in WFE do not apply to their VFC equivalents. If conflicting information exists in VFC and WFE, the changes in WFE are overridden the next time the synchronization process runs. However, if a non-VFC user is manually added to any of the WFE groups representing a synchronized VFC group, the user is not removed the next time the synchronization process runs.
Do not add WFE users manually to the default VFC group that holds all synchronized users.
The integration supports the migration of all VFC users, including users created by an Active Directory synchronization.
Synchronized VFC users do not have roles and privileges in WFE.
Switches and data sources
To synchronize the required recording data, the switch platforms for which the Integrator is configured must be specified in the appsettings.Production file of the Integrator.
The supported list of switch platforms is listed in the configuration file. The integration process does not run until one or more of the supported platforms is added to the list of configured platforms in the file.
Data sources in WFE do not have to be created manually, the Integrator automatically creates them to represent the switches configured in VFC. You must configure the Integrator to create the right WFE data sources for your deployment and monitoring needs by supplying switch configuration details in the appsettings.Production file.
You must specify:
- the VFC Recording Server addresses,
- the platform ID of the switch,
- the time zone of the switch,
- optionally, the extensions configured for that switch platform.
The granular configuration options in the Integrator allow for the accurate mapping of extensions to data sources in WFE.
You must add the addresses of all VFC Recording Servers that recorded calls to the data source configuration. Those Recording Servers that are not added do not have their calls synchronized to WFE.
A data source object in the appsettings.Production file can only be one platform type and must be in a single time zone. However, it can represent multiple switches of the same platform type, in the same time zone, being recorded by one or more VFC recorders. If the extensions are configured for the data source object, the specified extension numbers are associated to the WFE data source upon creation.
The extension parameter can be omitted or left empty for a data source object, which results in all extensions recorded by the specified recorders on the specified platform type to be associated with that data source. The extensions can be configured as an array of individual alphanumeric values or number ranges, but do not support wildcard operators.
If multiple identical data source objects exist in the appsettings.Production file without extension values specified, extensions for that platform type are associated with the WFE data source described by the first object.
If multiple data source objects exist in the appsettings.Production file without extensions specified but different platform types are set for them, extensions configured to record all platform types are associated to each data source.
If multiple identical data sources exist in the appsettings.Production file and some of them have extensions specified, the described extensions are associated with the corresponding data source created in WFE. The other, unspecified extensions are associated with the first data source that has no extensions added.
At a minimum, you must have one data source object without extensions per platform type. If you have data source objects with extensions specified, it is still recommended to have one data source without extensions specified to ensure that no missed extensions get excluded from the synchronization.
If a platform type has been added to the Configured Platforms parameter, but no data source objects exist in the Data Mapping section, no corresponding WFE data source is created, and no related recording data is synchronized to WFE.
The Integrator configures both the local and UTC time zone of a switch platform to the corresponding WFE data source. The Integrator configuration requires the time zone configured in the IANA time zone format <area>/<location>, but in the WFE user interface the time zone shows in both IANA and UTC/GMT-offset formats, depending on the application. For example, a switch at a site in Los Angeles is seen as America/Los_Angeles in Reports, but shows as GMT-08:00 Pacific Time (US & Canada) on the data source settings page under Recording Management.
Only a subset of IANA time zones are supported in WFE. You must configure a supported time zone value for the Integrator.
Refer to the Data Mapping section in the VFC to WFE Metadata Integrator Configuration Guide to select a supported time zone that represents your required time zone the closest.
For each configured data source in the appsettings.Production file, the Integrator searches WFE for an existing data source that meets the following criteria:
- It has the same name as the data source platform name configured in the DataMapping section of the appsettings.Production file.
- Its Type is Phone.
- Its Switch/sub-type is External Recorder.
- The Organization associated with the data source matches the organization ID of the parent organization created as part of the Integrator deployment process.
If the Integrator finds an existing data source with matching details, it notes the switch_ID of the WFE data source. If the Integrator does not find an existing data source with matching details.
All data sources created as part of the integration are created with the switch/sub-type External Recorder.
Recorders and call metadata
The Integrator migrates recording metadata to WFE by periodically checking the VFC database for new recording data and marking them for synchronization. Call marking is the process of reading in a call record from the database, evaluating it against the Integrator configuration, and sending it to the WFE database.
The Integrator only synchronizes recording metadata, not media files.
Each VFC installation is represented as a single recorder in WFE, and all synchronized call records get associated with this recorder, regardless of the number of distinct VFC recorders that captured the calls. Recorder servers in WFE are identified by a serial number that is automatically generated when the recorder is created. You must manually create an external recorder server in WFE for each VFC installation, and assign it a Serial Number that is unique to a VFC Media Repository. This serial number must be added to the appsettings.Production file of each Integrator that connects to the Media Repository described by the external recorder server. Refer to Create an External Server in Workforce Engagement for more information on adding an external server.
The way calls are recorded and stored is different in VFC and WFE. Refer to Data models for more details on the VFC call data models, and see Contacts and Interactions for information about the WFE call data models.
Due to the difference in the call record handling, the call search and replay functionality also differs in VFC and WFE. To keep the call search experience consistent across both systems for VFC users, the Integrator retains the VFC call model in WFE.
In WFE, every record in the search results under Interactions represents a single session from the WFE call model. In VFC, every record in the search results under Conversations represents a single conversation entry (CDR) from the VFC call model.
If more than one record was created during a conversation, related records can be shown together by selecting the ellipsis (…) button on the record and selecting Show Related.
During the synchronization process, each VFC conversation is mapped to a WFE session, allowing for the WFE call search experience being the same as in VFC.
To maintain the Show Related functionality, sessions are related to contacts and associated records can be viewed when selecting a call record from the search results.
The call records originating from WFE remain unchanged and a single record in the Interaction search results still represents a single session.
If the time interval between the start time of the first segment of a call and the start time of the last segment is longer than 12 hours, the created sessions in WFE are not associated with the same contact.
Prerequisites
- To access the WFE APIs, port 80 or 443 must be open on the WFE Application Server running the WFO_ProductionDomain_ProductionServer service for incoming communication from the Integrator.
- Ensure that the port configured for the VFC database is open on the server running the database to accept incoming communication from the Integrator.
Deployment process
The VFC to WFE Metadata Integrator deployment process requires configuration in the VFC and WFE environments before the installation of the Integrator. The configuration of the synchronization details is carried out in the appsettings.Production.json file of the Integrator tool after installation.
Install server certificates
- Open your browser in Administrator mode and go to your VFC Web Interface.
- Follow the Server Certificates topic to download the server certificate for the VFC Media Repository server from the VFC Certificate Authority.
- Install the downloaded certificate on VFC server that runs the Integrator service.
- In an on-premise or single-tenant WFE environment, sign in as Administrator. In a multi-tenant environment, sign in as Tenant Administrator.
- Follow the Create an organization topic in the WFE User Management Guide to set up an empty organization for the synchronized VFC data.
- Note the name of the organization created. You must enter the exact name in the appsettings.Production configuration file of each Integrator during the configuration process.
Create a parent organization in Workforce Engagement
Do not change the organization name once it has been configured for an Integrator.
Create a parent group in Workforce Engagement
- In an on-premise or single-tenant WFE environment, sign in as Administrator. In a multi-tenant environment, sign in as Tenant Administrator.
- Follow the Create a group topic in the WFE User Management Guide to set up an empty group for the synchronized VFC data.
No users must be assigned to the created parent group, or the synchronization process fails.
- Note the name of the group created. You must enter the exact name in the appsettings.Production configuration file of each Integrator during the configuration process.
Do not change the group name once it has been configured for an Integrator.
Create API key in Workforce Engagement for each WFE Tenant
- In an on-premise or single-tenant WFE environment, sign in as Administrator. In a multi-tenant environment, sign in as Tenant Administrator.
- Follow the Generate an API Key topic in the WFE Enterprise Configuration and Administration Guide to create an API key for each Integrator.
- Set Key type to External.
- When each API key is generated, note their Key ID and Key Value. You must enter the exact values in the appsettings.Production configuration file of each Integrator that synchronize data to this tenant during the configuration process.
- Sign in to VFC as an Administrator user.
- Follow the User Configuration topic to create a new user that is only used for submitting API requests to VFC.
- Set API Access Only to enabled.
- Note the user name and password of the created user. You must enter the exact values in the appsettings.Production configuration file of each Integrator during the configuration process.
Create a VFC API user account
Enable External Recorder data sources in Workforce Engagement
To enable External Recorder data sources that represent the VFC switch platforms, turn on the Data Marking API for External Recorder license item in WFE.
In a multi-tenant WFE environment, the service provider must carry out these steps. The tenant administrator cannot enable licenses or configure data sources.
- In a browser, go to http://<wfo_app_server_address>/wfo/control/license_edit.
- On the License Data page, under Features, enable 2021R1 - Data Marking API for External Recorder.
- Click Save.
Create an External Server in Workforce Engagement
To allow for accurate call marking, an External Server must be created in WFE to represent a VFC installation.
In a multi-tenant WFE environment, the service provider must carry out these steps. The tenant administrator cannot view or manage External Servers.
- Follow the Add an external server to the Installations tree topic in the WFE Enterprise Configuration and Administration Guide to create an external server.
- The Serial Number must be unique to both a VFC and a WFE installation. It must be a 6-digit number in the format XXXYYY, where the XXX is a 3-digit unique identifier for the VFC installation, and YYY is a 3-digit unique counter, incrementing for each Integrator.
- Repeat for all VFC installations. Ensure that the Serial Numbers are unique.
- Note the Serial Number of the created server or servers. You must enter the exact value in the appsettings.Production configuration file of each Integrator for a VFC installation during the configuration process.
(optional) Enable AQS in Workforce Engagement
If you have Voice Quality scoring enabled in VFC and would like the voice quality data synchronized, the WFE Audio Quality Statistics license item must be enabled.
In a multi-tenant WFE environment, the service provider must carry out these steps. The tenant administrator cannot enable licenses or configure data sources.
- In a browser, go to http://<wfo_app_server_address>/wfo/control/license_edit.
- On the License Data page, under Features, enable 2021R1 - Audio Quality Statistics.
- Click Save.
Install the Integrator
Follow the Installation Guide to install the VFC to WFE Metadata Integrator.
Configure the Integrator
Follow the Configuration Guide to configure the VFC to WFE Metadata Integrator.
Troubleshooting
Follow the Troubleshooting Guide to troubleshoot issues with the VFC to WFE Metadata Integrator.
Post-deployment tasks
After the migration completed, the following items must be completed and checked:
- Verify that the parent organization with the name specified during configuration exists in WFE.
- Verify that the parent group with the name specified during configuration exists in WFE.
- Verify that the VFC Synced group exists as a child of the parent group in WFE.
- Verify that the VFC user groups exist in WFE.
- Verify that VFC users are available in WFE, are associated with the same groups as in VFC, and have the right extensions associated to them.
- Verify that the data sources configured in the Integrator appsettings.Production file exist in WFE, and have the right name, time zone, and extensions associated with them.
- Verify that calls are accessible in the Automated Verification component of WFE.
- Verify that calls are associated with the right users, extensions, and data sources.
- Verify that calls are associated to the recorder with the virtual Serial Number specified in the Integrator.
Resilience
The VFC Integrator achieves a resiliency model using an active-passive design. Multiple Integrators can be running and be configured to read from the same VFC database per VFC environment, but only one Integrator is reading at once.
When an Integrator completes its initial dependency checks, it makes an internal note of all dependency statuses. If all dependencies are ready, the Integrator attempts to connect to the database to read data by sending the database a lock request. If no database locks are in place, the database grants the lock to the Integrator that requested it. The active Integrator keeps sending a heartbeat signal to the database to maintain ownership of the lock. While the ownership is allocated, the database declines any further lock requests from other Integrators.
Any Integrators that completed their dependency checks but were not granted the database lock remain in a passive state. In the passive state, Integrators periodically retries gaining ownership of the database lock. The period for reattempting to acquire the lock is 30% of the lock timeout value and is not modifiable. Before resubmitting the lock request, the passive Integrator checks its internal record of dependency statuses, and if all statuses are logged as ready, the Integrator sends the lock request. If any dependencies are not ready, the Integrator carries out another dependency check, and updates its record of statuses.
If the active Integrator fails and no heartbeat signal reaches the database, the lock timeout period starts. After the timeout period elapses, the lock is released, and the next Integrator to submit a lock request is granted database access. The lock timeout period is configurable in the appsettings.Production file of each Integrator.
Limitations
- The only WFE module with full functionality access through this integration is Automated Verification.
- If the time interval between the start time of the first segment of a call and the start time of the last segment is longer than 12 hours, the created sessions in WFE are not associated with the same contact.
- Passive Integrators that do not have ownership of the database lock use their internal record of the dependency statuses noted during the last dependency check to determine if all services are ready, and only run new dependency checks if any dependencies were previously not ready. This means that if a dependency was ready at the last dependency check but fails before the new lock request is sent to the database, the Integrator starts up and fails when it encounters the unavailable dependency, releasing the database lock and restarting the database lock timeout period. This can cause long wait times for Integrators competing for the database lock, as multiple Integrators failing can make the database connection unavailable for multiple consequent lock timeout periods.