...
- The data source name defined by WfeDatasource must be unique per WFE installation.
- The comma-separated list of VFC recorders defined by VfcServers must all be in the same time zone.
- VfcPlatform must be one of the values from the ConfiguredPlatforms parameter in the WFE section of the appsettings.Production file.
- There must be at least one data source object configured in this section for each platform specified in the ConfiguredPlatforms setting.
- The Extensions parameter can be omitted, in which case all existing extensions are associated with the data source. If included, the parameter is in the format of an array a comma-separated list of individual extensions or extension ranges. Individual extensions are supported in an alphanumeric format, while extension ranges are supported in the integer range format <startExtension>-<endExtension>. In extension ranges, both the startExtension and endExtension values are included as configured for the data source.
- The Timezone value must be specified in the IANA time zone format <area>/<location>. For example, Africa/Windhoek, or America/Los_Angeles.
...